Electrochemical test paper 2 channel desktop spray device
Description:
1. This equipment is developed for biochip and biosensor manufacturers.
2. A sealed protective cover is installed on the outside of the device, and a humidity controller is installed inside to ensure that the inside of the machine is suitable for the environmental requirements of the product. For special requirements, the reagent can be added with a temperature control system, which can guarantee a low temperature environment of 0-2 degrees.
3. For products with special needs, a high-precision laser measuring instrument can be added to accurately locate products with specific signs and color blocks (such as electrodes or other lines) printed on the surface. Or add a CCD visual control system to perform online detection for quality.
4. The device has a bus communication mode controller. Customized for special customers can increase remote communication to facilitate future equipment maintenance and software upgrades.
5. The needle or injection valve is easy to clean. The equipment is automatically completed during the cleaning process. The flow path pipeline, needle and other accessories can be removed and cleaned by themselves.
6. The operation interface is simple and clear, and the teaching mode is configured. Do not repeatedly flip the interface setting items, the logic is in line with human thinking, giving people a comfortable and relaxed working state
7. Only a small part of consumables are generated during the use of the equipment, and the consumables are standard parts with very low cost.
8. The equipment has complete functions and can be customized according to product characteristics: single point, straight line, circle, straight line spray, area area spray and other functions.
Item Parameter Remark
Worktable travel 100mm-600mm Determine worktable according to product size
Coordinate error + -0.02MM
Spotting full stroke accuracy <0.5%
Spotting full stroke accuracy ≤0.05%
Suction device can be selected
Syringe sizes from 50 μL to 50 mL can be configured on request
Standard dispensing / aspiration accuracy 6000 steps For example, if you choose a 50 microliter syringe, the minimum single step is: 50 divided by 6000 = 0.0833 microliter dose
Microstep distribution / suction accuracy 18000 steps For example, if you choose a 50 microliter syringe, the minimum single step is: 50 divided by 18000 = 0.0027 microliter dose
Precision <0.05% CV value during full run, at 25 ° C, use 1mL syringe deionized water)
Accuracy <1.0% CV value during full run, at 25 ° C, using 1mL syringe deionized water)